-40%

USB spectrometer, fiber input, software, LabView, VC, VB

$ 448.27

Availability: 46 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Return shipping will be paid by: Buyer
  • Model: LR1 spectrometer
  • Condition: New
  • Type: Light Meter
  • Country/Region of Manufacture: Canada
  • Brand: ASEQ Instruments

    Description

    Equipment for Spectroscopy
    Go to ASEQ Instruments web-site
    Mini spectrometers
    We offer custom design
    LR1 (v.16bits) – Broad spectral range spectrometer. USB interface
    Spectral range and spectral resolution can be customized
    examples on LabView are included in standard configuration
    Stadard configuration
    Weight:
    430 grams
    Dimensions:
    102 mm x 84 mm x 59 mm
    Detector:
    Toshiba TCD1304DG linear array
    Detector range:
    200 – 1100 nm
    Pixels:
    3648
    Pixel size:
    8 um x 200 um
    Pixel well depth:
    100,000 electrons
    Signal-to-noise ratio:
    400:1; 60000:1 (averaging mode)
    A/D resolution:
    16 bit
    Fiber optic connector:
    SMA 905 to 0.22 numerical aperture single-strand optical fiber
    Wavelength and
    Optical resolution:
    Configuration A:
    Spectral range: 300 – 1000 nm
    spectral resolution:
    < 3 nm
    (with 200 um fiber)
    < 1 nm
    (with 50 um slit)
    diffraction order filter installed
    Configuration B:
    Spectral range: 200 – 1200 nm
    spectral resolution:
    < 5 nm
    (with 200 um fiber)
    < 2 nm
    (with 50 um slit)
    Configuration C:
    Spectral range: 560 – 960 nm
    spectral resolution:
    < 1.3 nm
    (with 200 um fiber)
    < 0.4 nm
    (with 50 um slit)
    diffraction order filter installed
    Configuration D:
    Spectral range: 300 – 700 nm
    spectral resolution:
    < 1.3 nm
    (with 200 um fiber)
    < 0.4 nm
    (with 50 um slit)
    diffraction order filter installed
    (Spectral range and spectral resolution can be customized)
    Exposure time:
    10 microseconds – 60 seconds
    CCD reading time:
    10 ms
    Power consumption:
    150mA @ 5V from USB interface
    Onboard memory capacity:
    128 spectra
    Data transfer speed:
    150 ms / 100 ms (2 points binding)
    Trigger:
    3 modes (in LR1 some trigger modes are optional)
    Computer interface:
    USB 2.0, HID 2.0
    Operational system:
    Windows 10/Windows 8/Windows 7/Vista/XP  (32/64b)
    Software:
    application software, driver, LabView software, examples (VC, VB, Mathlab, Linux)
    Hardware:
    USB cable, 1 meter optical fiber with SMA connectors
    Warranty:2 years; Radiation measurements (47$ extra)
    contact:
    [email protected]
    Vancouver, Canada
    No shipping to some countries. Ask about shipping details.